Coriolis mass flow meter (CMD) MODEL PROLINE PROMASS

The Coriolis mass flow meters (CMD) simultaneously measure the mass flow of various media (liquids, gases, vapors), density, temperature and viscosity.

This simultaneous measurement opens up completely new perspectives for process control, quality assurance and plant protection. These primary measured variables can also be used to calculate other important parameters:

Volume flow rate
Solids content
Concentrations in multiphase media
Special density values such as standard density, °Brix, °Baumé, °API, °Balling or °Plato

The advantages of this measuring principle are:

  • Great applicability for a wide variety of media, such as Fuels (HFO, MDO, MGO) or gases (LNG)
  • Direct mass flow measurement
  • Complexity of the available measurands, e.g. Mass, density and temperature
  • Measurement independent of inlet and outlet sections, flows, density and temperature
  • Very high measuring accuracy
  • No moving parts
  • Large measuring range for a wide variety of applications

Proline Promass series Coriolis flowmeter Manufacturer Endress + Hauser (E+H)

Promass F is a long-established, highly accurate sensor. Insensitive to changing and demanding process conditions, it is suitable for the widest range of applications. With its compact transmitter, Promass F 300 offers high flexibility in operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and the extension of recalibration cycles.

Measuring principle works independently of physical medium properties such as viscosity and density

Highest measuring performance for liquids and gases under changing, demanding process conditions

Intelligent sensors with heartbeat technology

Do you want to increase the performance of your system and reduce costs? Thanks to Heartbeat Technology, our intelligent sensors have integrated diagnostics, verification and monitoring functions – for greater cost efficiency and operational reliability.

Proline Promass E 100
Proline Promass E 100
Proline Promass X 300
Proline Promass X 300
Proline Promass E 300
Proline Promass E 300
Proline Promass F 300
Proline Promass F 300

Max. Measuring deviation

Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0,10 %
Mass flow (gas): ±0,25 %
Density (liquid): ±0.0005 g/cm³

Measuring range

0…2 200 000 kg/h (0…80 840 lb/min)

Medium temperature range

Standard: -50…+150 °C (-58…+302 °F)
Option: -50…+240 °C (-58…+464 °F)
High-temperature option: -50…+350 °C (-58…+662 °F)
Option: -196 to +150 °C (-320…+302 °F)

Max. Process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)

Digital communication

HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Shipbuilding approvals and certificates

LR approval, DNV approval, ABS approval, BV approval, CCS approval